Causes and Solutions for Oil Leakage in Current Transformers

1. When there is material defect or welding leakage: If there is oil leakage in the oil reservoir or during welding, use leak stopper glue or electric welding methods. To prevent interference with the chromatographic analysis results of the oil, replace the oil after welding. If there is oil leakage in the weld of the expansion device, it should be replaced or re-welded. 2. When there is sealing leakage: If the sealing gasket is still elastic, it may be due to inconsistent...

Fuse Usage and Maintenance

When the fuse melts, it is necessary to carefully analyze the reasons for the melting. The main reasons are as follows: 1) Short-circuit faults or overload operation result in normal melting. 2) The fuse has been used for a long time, and due to oxidation or high operating temperature, the characteristics of the fuse have changed, causing it to malfunction. 3) There is mechanical damage during installation, causing the cross-sectional area of the fuse to decrease and resulting in malfunction during operation. When...

Safety Precautions for the Use of Fuses and Inspection Contents During Routine Checks

1. Safety precautions 1) The protective characteristics of the fuse should be compatible with the overload characteristics of the protected object. Based on the possible short-circuit current, select a fuse with the corresponding breaking capacity. 2) The rated voltage of the fuse needs to be adapted to the voltage level of the line. The rated current of the fuse should be greater than or equal to the rated current of the fuse element. 3) The rated currents of the fuse elements at...

Basic Requirements for Fuse Installation

1. The capacity of the fuse and the fuse element should comply with the design requirements, and the capacity of the protected electrical equipment should be matched with the fuse capacity. 2. The installation position and the distance between fuses should be convenient for replacing the fuse. 3. For fuses with fuse indication, the indicator should be installed on the side that is easy to observe. 4. When installing porcelain fuses on a metal base, the base should be padded with a...

Special Accidents and Maintenance Methods for Three-phase Combined Surge Arresters (also known as overvoltage protectors)

a. Inter-phase flashover caused by crossed two-phase insulated cables. Symptom: The upper end of the surge arrester is blackened, and the system has a phase-to-phase short circuit. Conclusion: Crossed two-phase insulated cables cause inter-phase surface flashover. Treatment: Separate the two-phase insulated cables to a certain distance. b. Inter-phase breakdown. Symptom: The upper end of the surge arrester is blackened, and the system has a phase-to-phase short circuit. Conclusion: Due to the limited space inside the cabinet, the three phases of the surge arrester did not...

What are the Structural Characteristics of A Fuse?

A fuse is mainly composed of a fuse element, a housing and a support. Among them, the fuse element is the key component that determines the fuse characteristics. 1. The material, size and shape of the fuse determine the fuse characteristics. 2. The fuse materials are divided into two types: low melting point materials and high melting point materials. Low melting point materials such as lead and lead alloys have a low melting point and are prone to melting, so their...

Damage and Handling Methods of Metal Oxide Surge Arresters

The damage of metal oxide surge arresters mainly occurs in two aspects. a. Aging of zinc oxide valve plates. b. Flashover at the interface between the valve plate and the external insulating material. The specific phenomena include the following. ① Phenomenon: Abnormally elevated DC reference voltage. Conclusion: Nonlinearity of zinc oxide valve plates has decreased. Treatment: Replace the entire surge arrester, or replace the zinc oxide valve plates. Cause: The rated voltage of the surge arrester is too low; the valve plates are not qualified. ②...

What are the Inspection Items for Lightning Arresters?

1. Normal inspection (1) The equalizing ring should be undamaged, and the ring surface should remain level; (2) The installation should not be skewed, and there should be no noise inside; (3) The base should be firm, without rust, and the grounding should be intact; (4) The porcelain bottle should be clean and undamaged, without cracks, discharge phenomena or flashover marks; (5) Check if the discharge counter is activated, whether there is moisture inside, and whether the upper and lower connection lines are intact; (6)...