E40L Residual Current Breaker with Overcurrent Protection

E40L Residual Current Breaker with Overcurrent Protection

Category:

E40L residual current operated circuit breaker is mainly applicable to AC 50/60Hz, rated voltage to AC240V, rated current to 40A terminal distribution line, providing overload, short circuit protection and residual current operated protection for the line, and also can perform infrequent switching operation for the line under normal conditions.

 

Features
1.Quick closing mechanism: instantaneous closing, efficient switching, reducing the risk of arcing and welding.
2. Integrated inlet and outlet structure: lower internal resistance, lower energy consumption and more energy conservation.
3.Bimetal bidirectional adjustment: bi-directional precise setting, suitable for multiple working conditions.
4.Super seismic optimization: stable seismic resistance, worry free in complex scenarios.

 

Functions
1. Overload protection
2. Short circuit protection
3. Residual current protection
4. Isolation function

 

Model and meaning

E40

L – C 40 1P A type、AC type
Enterprise

characteristic

code

Electronic

residual

current

protection

  Trip type Rated

current

(A)

Pole N0.

Residual current protection type

 

Dimensions

Technical Parameters
Product Model E40L
Rated current (A) 6、10、16、20、25、32、40
Rated voltage Ue (V) AC240V(1P)
Rated operating frequency (Hz) 50/60
Pole No. 1P
Mechanical life(times) 30000(Enterprise standard)
Electrical life(times) 15000(Enterprise standard)
Rated short-circuit capacity Icn(A) 10000
Rated operation short-circuit breaking capacity Ics(A) 10000
Rated insulation voltage Ui(V) 400
Rated impulse withstand voltage Uimp (kV) 4
Rated residual operating current I ∆ n(mA) 10、30、100
Residual current protection type A type、AC type
Trip Action Type Electronic type
Dielectric test voltage (V) 2000(50Hz、1min )
Anti-vibration (IEC/EN60068-2-6) No obvious vibration and impact
Wire terminal Minimum sectional area of connectable conductor (mm²) 1
Maximum sectional area of connectable conductor (mm²) 25
Standard connection torque (N·m) 3.5
Maximum allowable torque (N·m) 5
Lead insertion depth (mm) 10
Reference temperature (℃ ) 30
Operating temperature (℃ ) -35~+70
Storage temperature (℃ ) -35~+85
Applicable altitude (m) ≤ 2000
Form of tripping Thermal magnetic trip
Instantaneous tripping

characteristics

B type 3In-5In
C type 5In-10In
Wiring method Without limitation
Installation method TH35-7.5 Standard guide rail
Pollution capacity 2
Protection level Circuit breaker IP20
Installed in distribution box IP40