- Description
- Inquiry
E40L residual current operated circuit breaker is mainly applicable to AC 50/60Hz, rated voltage to AC240V, rated current to 40A terminal distribution line, providing overload, short circuit protection and residual current operated protection for the line, and also can perform infrequent switching operation for the line under normal conditions.
Features
1.Quick closing mechanism: instantaneous closing, efficient switching, reducing the risk of arcing and welding.
2. Integrated inlet and outlet structure: lower internal resistance, lower energy consumption and more energy conservation.
3.Bimetal bidirectional adjustment: bi-directional precise setting, suitable for multiple working conditions.
4.Super seismic optimization: stable seismic resistance, worry free in complex scenarios.
Functions
1. Overload protection
2. Short circuit protection
3. Residual current protection
4. Isolation function
Model and meaning
|
E40 |
L | – | C | 40 | 1P | A type、AC type |
| Enterprise
characteristic code |
Electronic
residual current protection |
Trip type | Rated
current (A) |
Pole N0. |
Residual current protection type |
Dimensions

| Technical Parameters | ||
| Product Model | E40L | |
| Rated current (A) | 6、10、16、20、25、32、40 | |
| Rated voltage Ue (V) | AC240V(1P) | |
| Rated operating frequency (Hz) | 50/60 | |
| Pole No. | 1P | |
| Mechanical life(times) | 30000(Enterprise standard) | |
| Electrical life(times) | 15000(Enterprise standard) | |
| Rated short-circuit capacity Icn(A) | 10000 | |
| Rated operation short-circuit breaking capacity Ics(A) | 10000 | |
| Rated insulation voltage Ui(V) | 400 | |
| Rated impulse withstand voltage Uimp (kV) | 4 | |
| Rated residual operating current I ∆ n(mA) | 10、30、100 | |
| Residual current protection type | A type、AC type | |
| Trip Action Type | Electronic type | |
| Dielectric test voltage (V) | 2000(50Hz、1min ) | |
| Anti-vibration (IEC/EN60068-2-6) | No obvious vibration and impact | |
| Wire terminal | Minimum sectional area of connectable conductor (mm²) | 1 |
| Maximum sectional area of connectable conductor (mm²) | 25 | |
| Standard connection torque (N·m) | 3.5 | |
| Maximum allowable torque (N·m) | 5 | |
| Lead insertion depth (mm) | 10 | |
| Reference temperature (℃ ) | 30 | |
| Operating temperature (℃ ) | -35~+70 | |
| Storage temperature (℃ ) | -35~+85 | |
| Applicable altitude (m) | ≤ 2000 | |
| Form of tripping | Thermal magnetic trip | |
| Instantaneous tripping
characteristics |
B type | 3In-5In |
| C type | 5In-10In | |
| Wiring method | Without limitation | |
| Installation method | TH35-7.5 Standard guide rail | |
| Pollution capacity | 2 | |
| Protection level | Circuit breaker | IP20 |
| Installed in distribution box | IP40 | |
English
Spanish
Russian