E63L Earth Leakage Circuit Breaker
- Description
- Inquiry
Type A & Type AC
|
Product parameters |
1P+N | 3P+N | 3P | |
|
Size(mm) |
36 | 81 | 72 | |
| Module | 2
modules |
4.5
modules |
4 modules |
|
|
Characteristics |
Short circuit protection, overload
protection, leakage protection, N-pole with breaking capacity |
Short circuit protection, overload protection, and leakage protection | ||
| Wiring method | Top incoming/bottom outgoing (w/wiring
mark), naught wire mark |
Top incoming/ bottom outgoing (w/wiring mark) |
||
|
Rated current (A) |
1、2、4、6、10、16、20、25、32、40、50、63 | |||
| Rated leakage current (mA) |
10、30、100、300、500 |
|||
|
Leakage trip type |
AC type, A type | |||
| Rated voltage (V) Un | 230 |
400 |
||
|
Rated insulation voltage (V) Ui |
500 | 500 | ||
| Rated operating frequency (Hz) |
50/60 |
|||
|
Rated impulse withstand voltage (V) Uimp |
4000 | |||
| Rated short-circuit capacity Icn |
6000 |
|||
|
Rated short-circuit breaking capacity Ics |
6000 | |||
| Overvoltage category |
Ⅱ |
|||
|
Pollution capacity |
2 |
|||
|
Instantaneous tripping characteristics |
B(3In-5In) |
Yes | ||
| C(5In-10In) |
Yes |
|||
| D(10In-20In) |
Yes |
|||
|
Electric shock protection level |
Ⅱ | |||
| Mechanical characteristics mechanical life |
20000 |
|||
|
Protection level |
Circuit breaker | IP20 | ||
| Installed in the
distribution box |
IP40 |
|||
|
Maximum wiring capacity(²) |
50 | |||
| Terminal ultimate torque (Nm) |
5 |
|||

Type B
|
Product parameters |
1P+N | 3P+N | 3P | |
|
Size(mm) |
54 | 90 |
90 |
|
|
Module |
3
modules |
5
modules |
5
modules |
|
| Characteristics | Short circuit protection, overload
protection, leakage protection, N-pole with breaking capacity |
Short circuit protection, overload protection, and leakage protection |
||
|
Wiring method |
Top incoming/bottom outgoing (w/wiring
mark), naught wire mark |
Top incoming/
bottom outgoing (w/wiring mark) |
||
| Rated current (A) |
1、2、4、6、10、16、20、25、32、40、50、63 |
|||
|
Rated leakage current (mA) |
10、30、100、300、500 | |||
| Leakage trip type |
B type |
|||
|
Rated voltage (V) Un |
230 | 400 | ||
| Rated insulation voltage (V) Ui | 500 |
500 |
||
|
Rated operating frequency (Hz) |
50/60 | |||
| Rated impulse withstand voltage (V) Uimp |
4000 |
|||
|
Rated short-circuit capacity Icn |
6000 | |||
| Rated short-circuit breaking
capacity Ics |
6000 |
|||
|
Overvoltage category |
Ⅱ | |||
| Pollution capacity |
2 |
|||
|
Instantaneous tripping characteristics |
B(3In-5In) |
Yes | ||
|
C(5In-10In) |
Yes |
|||
| D(10In-20In) |
Yes |
|||
|
Electric shock protection level |
Ⅱ |
|||
| Mechanical characteristics mechanical life | 20000 | |||
|
Protection level |
Circuit breaker | IP20 | ||
| Installed in the
distribution box |
IP40 |
|||
|
Maximum wiring capacity(²) |
50 |
|||
| Terminal ultimate torque (Nm) |
5 |
|||

English