ENC Miniature Circuit Breaker(MCB) Advantages:
1. Higher Rate Current
ENC has pushed smallcircuit breakers to a new height of 160A.
2. Higher Breaking Capacity
The breaking capacity of ENC MCB reaches 15000A.
The E125M and M63H series MCB are high breaking circuit breakers.
3. Lower Energy Consumption
ENC MCB is equipped with an integrated solderless coil as standard, reducing 3-5 welding points.
The energy consumption level of ENC MCB is 1/2 to 1/3 of the international standard.
4. More Precise Tripping
ENC MCB is equipped with bidirectional setting technology as standard, ensuring that the circuit breaker will break when it breaks.
5. Faster closure
ENC MCB is equipped with energy storage quick closing function as standard, ensuring safer operation.
|
Rated current (A) |
160A,125A,100A,80A,60A | ||||
|
Product parameters |
1P | 2P | 3P | 4P | |
| Size (mm) | 27 | 54 | 81 |
108 |
|
|
Module |
1.5
Modules |
3
Modules |
4.5
Modules |
6
Modules |
|
| Characteristics |
Short-circuit protection, overload protection |
||||
|
Wiring method |
Without limitation | ||||
| Rated voltage (V) Un | 230/240 |
415/440 |
|||
|
Rated insulation voltage (V) Ui |
1000 | ||||
| Rated operating frequency (Hz) |
50/60 |
||||
|
Rated impulse withstand voltage (V) Uimp |
6000 |
||||
|
Rated short-circuit capacity Icu |
10000 |
||||
|
Rated operation short-circuit breaking capacity Ics |
10000 |
||||
|
Overvoltage type |
Ⅱ | ||||
| Pollution capacity |
3 |
||||
|
Instantaneous trip characteristics |
C(7In±20%) | Yes | |||
| D(13In±20%) |
Yes |
||||
|
Electric shock protection level |
Ⅱ |
||||
|
Time-delay tripping characteristic (reference temperature 30±2℃ ) |
Rated Non-Trip
Current |
≤ 63A 1.05In 1H,> 63A 1.05In 2H | |||
| Agreed Tripping
Current |
≤ 63A 1.3In 1H,> 63A 1.3In 2H |
||||
|
Mechanical Characteristics [Mechanical Life (Cycles)] |
7000 |
||||
|
Electrical Life [Rated Current (Cycles)] |
1000 |
||||
|
Level of protection |
Circuit breaker | IP20 | |||
| Installed in the
distribution box |
IP40 |
||||
|
Max. wiring capacity (²) |
70 | ||||
| Terminal maximum torque (Nm) |
10 |
||||
|
Terminal Temperature Rise(1.05In) |
≤ Environmental Temperature+40℃ | ||||
| Operating Temperature Range |
-20℃~ +50℃ |
||||
|
Storage Temperature |
-20℃~ +60℃ | ||||
| Damp heat resistance |
When the ambient air temperature is 55℃, the relative air humidity is ≤ 95% |
||||
|
Altitude requirement |
≤ 2000m |
||||
| Installation method |
M35 Rail Mounting |
||||
|
M160 Types |
|||
|
E160 1P |
E160 2P | E160 3P |
E160 4P |
|
E160 C60 1P |
E160 C60 2P | E160 C60 3P | E160 C60 4P |
| E160 D60 1P | E160 D60 2P | E160 D60 3P |
E160 D60 4P |
|
E160 C80 1P |
E160 C80 2P | E160 C80 3P | E160 C80 4P |
| E160 D80 1P | E160 D80 2P | E160 D80 3P |
E160 D80 4P |
|
E160 C100 1P |
E160 C100 2P | E160 C100 3P | E160 C100 4P |
| E160 D100 1P | E160 D100 2P | E160 D100 3P |
E160 D100 4P |
|
E160 C125 1P |
E160 C125 2P | E160 C125 3P | E160 C125 4P |
| E160 D125 1P | E160 D125 2P | E160 D125 3P |
E160 D125 4P |
|
E160 C160 1P |
E160 C160 2P | E160 C160 3P |
E160 C160 4P |
| E160 D160 1P | E160 D160 2P | E160 D160 3P |
E160 D160 4P |
English
Spanish
Russian